Measure where the target actually is.
Compare irradiance at repeatable distances instead of assuming the panel's rated electrical power equals delivered light intensity.
Panel wattage alone does not tell you how much light reaches a specific position or distance. AH-REDNIR measures the 660nm red-light channel and 800–1000nm near-infrared channel, then lets you view irradiance on your phone through Bluetooth.
Red/NIR panels can produce different irradiance at different distances and across different parts of the panel. AH-REDNIR is designed to turn those differences into numbers you can compare.
Compare irradiance at repeatable distances instead of assuming the panel's rated electrical power equals delivered light intensity.
Take readings across the treatment area to see whether output is even or whether some regions are stronger or weaker.
Keep distance and position consistent, then compare measured irradiance rather than relying only on advertised wattage.
The current product listing specifies simultaneous measurement of 660nm red light and 800–1000nm infrared output. Common 850nm near-infrared LEDs fall within the NIR channel.
Measure the 660nm red-light channel and view the irradiance numerically instead of judging brightness by eye.
Measure near-infrared output across the specified 800–1000nm channel, including common 850nm NIR panel applications.
The supplied product imagery shows separate 660nm and 800–1000nm values together with an overall irradiance reading in the phone interface.
A single center reading cannot describe an entire panel. Measure several positions at the same distance to compare irradiance distribution.
Use the same sensor orientation and distance at every point. This makes it easier to distinguish panel distribution differences from changes in measurement setup.
Measure at the distance relevant to your comparison and keep that distance constant across the grid.
Check the center, corners, edges or any other positions you want to compare.
If distance falloff matters, repeat the same positions at the next distance and compare the measured irradiance.
The current listing states that AH-REDNIR pairs with a mobile app through Bluetooth and works when the phone has no internet connection.
Clear product boundaries help customers — and search/AI systems — understand exactly what this meter is for.
AH-REDNIR is a portable irradiance meter for red and near-infrared LED panels. It measures a 660nm red-light channel and an 800–1000nm near-infrared channel and can display readings on a phone through Bluetooth.
Yes. The current product listing is positioned for 660nm red light and near-infrared output used by common 850nm panels. The NIR measurement channel is specified as 800–1000nm.
The Bluetooth app can display irradiance in mW/cm² or W/m².
Yes. Take measurements at repeatable positions while keeping distance and sensor orientation consistent. This lets you compare irradiance distribution across the panel.
No. The current product listing states that the meter connects through Bluetooth and works even when the phone is offline.
No. AH-REDNIR is a red/NIR irradiance meter. PAR or PPFD requires a meter designed for photosynthetically active radiation.
No. AH-REDNIR is a light-measurement instrument. It reports irradiance and does not diagnose conditions or prescribe treatment.
This page refers specifically to the AquaHorti AH-REDNIR red and near-infrared irradiance meter.
AquaHorti AH-REDNIR combines 660nm red-light measurement, 800–1000nm NIR measurement, mW/cm² / W/m² readouts and Bluetooth phone viewing for practical panel comparisons.