AH
AquaHorti AH-Quantuv · PAR / PPFD + UVA + Blue / Green / Red PAR
AquaHorti AH-Quantuv · Handheld Grow-Light Spot-Check Meter

AH-Quantuv handheld grow-light PAR meter — compare real light at the plant canopy.

Use AH-Quantuv for fast in-air checks at the plant canopy when comparing different LED grow lights, dimming settings, mounting heights, or positions across a grow area. It measures PAR / PPFD from 400–750 nm, UVA from 320–400 nm, and shows Blue, Green, and Red PAR contributions separately.

01 PAR / PPFD
02 UVA 320–400 nm
03 Separate B / G / R PAR
04 Up to 100 readings
Price: $64.80 U.S. reference price. Price and availability may vary.
Purchase options and the PDF manual open in a new tab.
AquaHorti AH-Quantuv PAR meter screens showing PPFD, UVA, Blue Green Red PAR components, and recorded readings
One handheld meter.
Dedicated views for different questions.
PAR · UVA · RGB PAR · History
Built for grow-light decisions

Measure, adjust, and measure again — directly at canopy level.

AH-Quantuv is not positioned around an all-day logging workflow or a continuous spectrum report. Its core job is fast, repeatable grow-light comparison: place the meter where the plants are, take a reading, change one variable, and check what actually changed.

Fixture comparison

Compare Grow Light A vs. Grow Light B

Use the same canopy position and height to compare total PPFD, UVA and Blue / Green / Red PAR contribution.

Dimming

Check what a dimming change really does

Measure before and after changing the dimmer instead of assuming the percentage setting equals the same percentage change in light.

Mounting height

Test different fixture heights

Move the fixture, keep the canopy measurement point consistent, and compare the resulting PPFD and spectral-component readings.

Coverage mapping

Check center, edges, shelves and rows

Store up to 100 PAR measurements to compare multiple positions and find hotspots or low-light zones across the grow area.

Product identity: AH-Quantuv is AquaHorti's handheld grow-light spot-check model for PAR / PPFD + UVA + Blue / Green / Red PAR. AH-Reef is the separate underwater reef-aquarium model, while AH-PARDLI is the separate all-day PAR / DLI logging workflow.
Why choose AH-Quantuv?

Compare grow lights with more than one total PAR number.

The buying question is not simply “Does it measure PAR?” Many meters do. The more useful question is: What can I learn after I get the PAR number?

What you want to know
Typical single-value PAR meter
AH-Quantuv
How much photosynthetic light reaches the canopy?
✓Total PAR / PPFD
✓PAR / PPFD
Does the grow light actually produce UVA?
—Usually not shown
✓Direct UVA irradiance reading
How do Blue, Green, and Red PAR components compare?
—Usually combined into one total
✓Separate B / G / R PAR views
Can I save multiple points while tuning a setup?
—Depends on the meter
✓Record readings for comparison / mapping
Can one meter help answer more than “how much light”?
—Primarily an intensity measurement
✓Intensity + UVA + spectral-component insight
The mathematical difference

One scalar vs. a richer measurement set

1 → 5

A single PPFD value is one number. AH-Quantuv gives you several measured dimensions to compare:

PPFD UVA Blue Green Red
Why this matters to the buyer

The same total number does not necessarily mean the same light.

If Light A and Light B both show the same PPFD, a total-only reading cannot tell you whether their UVA output or Blue / Green / Red distribution differs. AH-Quantuv gives you additional measured values, so comparison is based on more information instead of assuming that one equal total means two equal light profiles.

What makes it different

See more of the spectrum behind the PAR number.

AH-Quantuv extends the conversation beyond total PAR / PPFD by adding UVA irradiance and separate Blue, Green, and Red PAR measurements.

AH-Quantuv 320 to 750 nm measurement coverage
320–750 nm coverage

Go beyond one total reading

A total PAR number is useful, but it compresses many wavelengths into one result. AH-Quantuv gives you additional views so you can inspect more of the light behind that number.

UVA 320–400 Blue 400–500 Green 500–600 Red 600–750
AH-Quantuv UVA irradiance measurement
UVA irradiance

“Full spectrum” is a label. UVA is a measurement.

When a grow light claims broad or full-spectrum output, AH-Quantuv lets you measure UVA irradiance directly instead of assuming UVA is present from marketing language alone.

AH-Quantuv separate Blue Green Red PAR components
Separate RGB PAR

Total PAR can hide composition.

AH-Quantuv shows Blue, Green, and Red PAR components separately. That makes it easier to compare different fixtures or settings even when their total readings look similar.

A better decision process

Buy the meter that answers the next question — not only the first one.

PAR / PPFD answers “how much.” AH-Quantuv is designed to help you keep going after that first answer.

01 · MEASURE

Start with total PPFD

Measure at the canopy or plant position you actually care about.

02 · VERIFY

Check UVA directly

Measure UVA output directly instead of relying only on fixture claims.

03 · COMPARE

Look at B / G / R separately

Compare spectral components when two lights or settings have similar total PAR.

04 · TUNE

Record and repeat

Save measurement points while changing height, dimming, or fixture position.

Built for real grow work

Measure one point — or build a picture of the whole grow area.

A single center reading can miss what happens at the edges. Recording multiple points makes coverage differences visible.

AH-Quantuv recorded PAR and UVA readings for grow-light coverage mapping

Record history for PAR / UVA mapping

Store up to 100 PAR measurements to compare canopy positions and check whether light coverage is even across the grow area.

AH-Quantuv handheld PAR meter size

Handheld for fast spot checks

Move between shelves, corners, rows, or canopy positions quickly — useful when you want to measure, adjust, and measure again.

The numbers become decisions

PPFD is instantaneous. Time turns it into a daily quantity.

The calculator below shows why a seemingly small PPFD difference can accumulate over many hours. This is a mathematical conversion, not a plant-specific recommendation.

DLI = PPFD × light-hours × 0.0036

Example: 500 vs 600 PPFD for 12 hours/day produces a DLI difference of 4.32 mol/m²/day.

DLI FROM READING A 21.60 mol/m²/day
DLI FROM READING B 25.92 mol/m²/day
DAILY DIFFERENCE +4.32 mol/m²/day · +20.0% PPFD vs Reading A
See it in action

Watch AH-Quantuv in a real measurement workflow.

Frequently asked questions

Know exactly what AH-Quantuv is for.

These answers keep the grow-light use case and AH-Quantuv model identity clear.

What is AquaHorti AH-Quantuv designed for?

AH-Quantuv is designed for fast in-air grow-light spot checks at the plant canopy. It is useful for comparing LED fixtures, dimming settings, mounting heights and different positions across a grow area.

What does AH-Quantuv measure?

It measures PAR / PPFD across 400–750 nm and UVA irradiance across 320–400 nm, and shows the PAR contribution of Blue 400–500 nm, Green 500–600 nm and Red 600–750 nm separately.

Can I compare two grow lights or two dimming settings?

Yes. Measure at the same canopy position and height before and after changing the fixture, dimming level or mounting height. This keeps the comparison focused on the lighting change.

How many measurements can AH-Quantuv store?

The current product listing specifies storage for up to 100 PAR measurements for light-distribution mapping and comparison across a grow area.

Does AH-Quantuv require a phone app for spot measurements?

No phone app is required for the published handheld measurement functions. PAR, UVA, RGB PAR breakdown and historical records are available through the meter's display modes.

Is AH-Quantuv an all-day DLI logger?

AH-Quantuv is positioned primarily as a handheld spot-check and multi-point mapping meter. For tracking PAR over time and calculating DLI across the day, AquaHorti uses the separate AH-PARDLI workflow.

Is AH-Quantuv the underwater reef model?

No. AH-Quantuv is positioned for grow-light measurement in air. AquaHorti AH-Reef is a separate model for underwater reef-aquarium light measurement.

Grow-light spot checks with more context

Compare LED grow lights where the plants actually receive the light.

AH-Quantuv combines PAR / PPFD, UVA irradiance, separate Blue / Green / Red PAR components, HOLD and up to 100 stored PAR measurements in one handheld tool for comparing fixtures, dimming, mounting height and canopy coverage.

Price: $64.80 U.S. reference price. Price and availability may vary.
PAR / PPFD UVA irradiance Separate Blue / Green / Red PAR Record readings